ATM-06D

Advanced 16-channel logger, recorder with UNIVERSAL PROGRAMMABLE inputs (ethernet, gsm, sms, snmp, soap)

Advanced 16-channel logger, recorder with UNIVERSAL PROGRAMMABLE inputs (ethernet, gsm, sms, snmp, soap)

  • -

Price

staffelprijzen op aanvraag

Availability: In stock

€1,695.00
Delivery

Call ATAL (+31) (0)299 630 610

General

-0

Specifications

Total memory capacity 2MB (up to 480 000 values)
Memory type internal SRAM, backed-up by Lithium battery
Data logging modes noncyclic - logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Data logging interval adjustable individually for all input channels from 1 second to 24 hours
Real time clock year, leap year, month, day, hour, minute, second, backed-up by Lithium battery
Resolution of the AD converter (analog channels) 16 bits, conversion duration approximately 60ms/channel
Communication speed 9600, 19200, 57600, 115200 Bd, 230400* Bd (* applicable for USB, Ethernet)
Power 24Vdc, consumption of data logger itself approximately 80 mA
Operating temperature range 0 to +50°C
Dimensions including connectors 215 x 225 x 44 mm (W x D x H)
Protection IP20
Weight approximately 800 g

Accesories

  1. Split Core
    • Deelbereiken instelbaar 0-30, 60, 120A
    • Analoge output: 4-20mA
    • Makkelijke installatie

    Out of stock

  2. Split Core
    • Deelbereiken instelbaar 0-30, 60, 120A
    • Analoge output: 0-5V
    • Makkelijke installatie
    • Geen voeding nodig

    Out of stock

  3. Split Core
    • Deelbereiken instelbaar 0-20, 100, 150A
    • Analoge output: 0-10V
    • Makkelijke installatie
    • Geen voeding nodig

    Out of stock

  4. 16-channel Relay Expansion Module
    • Incl. 16 relays with NO/NC contact
    • For use with ATM-05 and ATM-05D system
    Price
    €445.00
  5. External LCD module
    • For conecting with ATM-05 and ATM-05D system
    • Equipped with LED indicators and function keys
    • Suitable for panel mounting (excluding cable)
    Price
    €298.00
  6. External LCD module, complete embedded in a plastic casing
    • For conecting with ATM-05 and ATM-05D system
    • Equipped with LED indicators and function keys
    • Completely built in a plastic housing for wall mounting
    • Incl. 2m cable
    Price
    €365.00
  7. RS232 (PC) > RS485 (ATM) converter
    • For communication over distances longer than 10m
    Price
    €195.00
  8. Acoustic indicator for local alarming
    • Acoustic indicator for local alarming
    • will be connected to the voltage alarm output
    Price
    €25.00
  9. Integrated Ethernet interface
    • Integrated Ethernet interface
    • For communication with ATM-055, ATM-055D and ATM-06D via Ethernet
    Price
    €190.00
  10. External converter USB > RS485
    • USB (PC)> RS485 (ATM) converter
    • For communication over distances longer than 10m.
    • For older types of ATM systems without USB connector
    • RS232 (PC) > USB (ATM) converter
    • for communication with ATM-Plus via USB port
    Price
    €130.00
  11. Metal brackets
    • To mount against the wall ATM-05(D) or Relay Expansion Module
    Price
    €12.00
  12. Bevestigings accessoire voor ATM-05 of ATM-05D op DIN-rail
    • Accessoire om de ATM-05 of ATM-05D op een DIN-rail te kunnen bevestigen.
    Price
    €22.00
  13. Accessory to mount Relais Extensibility Module on a DIN-rail
    • Accessory to mount Relais Extensibility Module on a DIN-rail
    Price
    €22.00
  14. Connection cable between ATM-05 and external Relais Module / external LCD display (10m)
    • Connection cable
    • Length 10m.
    Price
    €59.00
  15. Connection cable between ATM-05 and external Relais Module / external LCD display (5m)
    • Connection cable
    • Length 5m.
    Price
    €42.00
  16. Connection cable between ATM-05 and external Relais Module / external LCD display (60cm)
    • Connection cable
    • Length 60cm.
    Price
    €27.00
  17. Special WAGO screwdriver
    • Special WAGO screwdriver for easy cabling finish at WAGO connector
    Price
    €10.00
  18. Robust IP65 enclosure complete with DIN-rail
    • IP65 enclosure
    • Robust design
    • Suitable to mount on a ATM-05 (D)
    Price
    €110.00
  19. Ethernet (PC) > RS485 (ATM) converter
    • Ethernet (PC) > RS485 (ATM) converter
    • Multiple ATM systems can be networked and can be attached to one ethernet outlet
    Price
    €425.00
  20. Power supply (DIN-rail mounting) 24Vdc
    • 24Vdc, incl. DIN-rail 100mm
    Price
    €119.00
  21. Windows® Analysis Software
    • Windows Software
    • Very extensive graphical analysis possibilities
    Price
    €198.00

Applications

Cooling

For a good and efficient operation of the refrigerating equipment registration is necessary. Checking switch on / switch off times and control behavior can easily be established through registration.

Energy Management

By switching behavior of electricity consumers and increase frequency of scheduled installations the tensions, flows and cos phi could greatly vary. By registering, you will better understand the variations of voltage, current and cos phi.

Food production and distribution (HACCP)

HACCP is a hygiene code for the food industry and stands for Hazzard Analysis Critical Control Points. The biggest factor that affects the decay of food is the temperature and thereby the growth of micro-organisms

Data centre, telecommunication and cleanrooms

Data and telecom spaces have increasingly more difficulty to control the cooling of the established ICT equipment. Because more and more power-using computer systems can be placed in a System or 19" rack, the specific heat load rises per m2 computer room. By timely handling of heat problems costly downtime can be avoided.

Industry

In various industrial applications, the monitoring from processes are essential. Thus, for example, the pharmaceutical industry is one of the largest users of moisture measuring equipment. Most drugs are sensitive to variations in moisture levels, so this should be monitored and measured so that the finished products are consistent in quality and performance.

Laboratories (GMP / GLP)

Within a laboratory, the conditions of the room in which scientific research and experiments are kept have to fall within certain limits. In addition to the space conditions the temperature is recorded and monitored for refrigerators and freezers, CO2 braise, sterilization equipment, disinfection equipment etc.

Meteo

Instruments to monitor wind speed, wind direction, temperature, humidity and barometric pressure with analog outputs for the measurement and control of HVAC installations.

Research and Development

Before actually a product is marketed the product is extensively tested. Parameters such as temperature, humidity, flow, pressure, power, light intensity, voltage and power consumption are much sought parameters that are easy connected on the ATAL monitoring systems.

Downloads

Software

You must login to download software

Login | Register

Reviews

Only registered users can write reviews. Please, log in or register